VRVP2012- Gauge Pressure Transmitter
VRVP2013- Absolute Pressure Transmitter
Thepressure transmitter VRVP2012/3 is suitable to measure liquid, gas, or steamflow as well as liquid level, density and pressure. VRVP2012/3 outputs a 4 to20 mA DC signal corresponding to the measured pressure. The key featuresinclude quick response, remote set-up using communications, self-diagnosticsand optional status output for pressure high/low alarm.
STANDARD SPECIFICATIONS
1 PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span (includesterminal-based linearity, hysteresis, and repeatability)
± 0.075%;
If TD>10 (TD=URL/SPAN):
±(0.0075×TD)%;
Ambient Temperature Effects
Span Code | -20℃~65℃ |
B/L | ±(0.30×TD+0.20)%×Span |
Others | ±(0.20×TD+0.10)%×Span |
Span Code | -40℃~-20℃和65℃~85℃ |
B/L | ±(0.30×TD+0.20)%×Span |
Others | ±(0.20×TD+0.10)%×Span |
Overpressure Effects
±0.075%×Span
Stability
Span Code | Stability |
B/L | ±0.2%×Span/1year |
Others | ±0.1%×Span/1year |
Power Supply Effects:
±0.001% /10V (12~42V DC)
2 FUNCTIONAL SPECIFICATIONS
Span and Range Limits (VRVP2012)
Span/Range Limits | kPa | bar |
1B | Span | 0.6~6 | 6~60mbar |
Range Limits | -6~6 | -60~60mbar |
1C | Span | 2~40 | 0.02~0.4 |
Range Limits | -40~40 | -0.4~0.4 |
1D | Span | 2.5~250 | 0.025~2.5 |
Range Limits | -100~250 | -1~2.5 |
1F | Span | 30~3000 | 0.3~30 |
Range Limits | -100~3000 | -1~30 |
1G | Span | 0.1~10MPa | 1~100 |
Range Limits | -0.1~10MPa | -1~100 |
1H | Span | 0.21~21 MPa | 2.1~210 |
Range Limits | -0.1~21 MPa | -1~210 |
1I | Span | 0.4~40 MPa | 4~400 |
Range Limits | -0.1~40 MPa | -1~400 |
Span and Range Limits (VRVP2013)
Span/Range Limits | kPa | bar |
1L | Span | 2~40 | 0.02~0.4 |
Range Limits | 0~40 | 0~0.4 |
1M | Span | 2.5~250 | 0.025~2.5 |
Range Limits | 0~250 | 0~2.5 |
1O | Span | 30~3000 | 0.3~30 |
Range Limits | 0~3000 | 0~30 |
External Zero Adjustment
External zero is continuously adjustable with 0.01%incremental resolution of span. Re-range can be done locally using the rangesetting switch.
Mounting Position Effects
Rotation in diaphragm plane has no effect. Tilting up to90 degree will cause zero shift up to 0.4 kPa which can be corrected by thezero adjustment.
Output
Two wire 4 to 20 mA DC output with digitalcommunications, linear or square root programmable. HART FSK protocol is option superimposed onthe 4 to 20 mA signal. Output range: 3.9 mA to 20.5 mA
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
No Mode (hold): Keep the effective value before fault.The standard setting of failure alarm is High Mode.
Response Time
Theamplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6sec, it depends on the range and range compression ratio. Amplifier dampingtime constant is adjustable from 0 to 60 sec by software and added to responsetime.
Up Time < 15s
Ambient Temperature Limits: -40 to 85°C
-20 to 65°Cwith LCD display or fluorine rubber sealing
Storage and Transportation Temperature Limits
-50 to 85°C, -40 to 85°Cwith LCD display
Working PressureLimits (Silicone oil)
From vacuum toupper range limits
Overload Pressure Limits
Span | 6kPa (1B) | 40kPa (1C) | 250kPa (1D/1M) | 2(3)MPa (1E/1O) |
OPL | 16MPa | 16MPa | 16MPa | 16MPa |
Span | 10MPa (1G) | 21MPa (1H) | 40MPa (1I) |
OPL | 20MPa | 50MPa | 50MPa |
Electromagnetic Compatibility (EMC)
Look the EMC Performance Table
3 INSTALL
Supply & Load Requirements
24 V DC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximumvoltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(withLCD display)
230Ω to 600Ω for digital communication
Electrical Connection
The electrical connection is made via cable entryM20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2.
Process Connection
Default Process Connection:Flange withfixing thread 7/16-20 UNF and 1/4-18 NPT female thread on both sides.
4 PHYSICAL SPECIFICATIONS
IsolatingDiaphragm:316L stainless steel/Hastelloy C
Process Connector: 316 stainlesssteel
Fill fluid: Silicone oil
Amplifier Housing: Aluminum with epoxy resin coat
Housing Gasket: Perbunan(NBR)
Name plate and tag:304 stainless steel
Weight: 3.3kg
Degrees of Protection: IP67
EMC Performance Table
Items | Test items | Basic standards | Test conditions | Performance Level |
1 | Radiated interference (Housing) | GB/T 9254-2008 | 30MHz~1000MHz | OK |
2 | Conducted interference(DC power port) | GB/T 9254-2008 | 0.15MHz~30MHz | OK |
3 | Electrostatic Discharge (ESD) Immunity | GB/T 17626.2-2006 | 4kV(Line) 8kV(Air) | B |
4 | RF electromagnetic field immunity | GB/T 17626.3-2006 | 10V/m (80MHz~1GHz) | A |
5 | Frequency magnetic field immunity | GB/T 17626.8-2006 | 30A/m | A |
6 | Electrical Fast Transient Burst Immunity | GB/T 17626.4-2008 | 2kV(5/50ns,5kHz) | B |
Note:(1)Performancelevel A description: The technical specifications within the limits of normalperformance.
(2)Performancelevel B description: Temporary reduction or loss of functionality orperformance, it can restore itself. The actual operating conditions, storage,and data will not be changed.
DIMENSIONS Unit : mm
HorizontalImpulse Piping Type(side face) Horizontal Impulse Piping Type(frontside)
Horizontal Impulse Wall mounting Type Vertical ImpulsePiping Type
5 Terminal Configuration
Note:Quick interface functionally equivalentto the signal terminal
6 Process connections Description
7 Model and suffix codes
Gauge Pressure Transmitter VRVP2012- | |
Absolute Pressure Transmitter VRVP2013- | |
10 | Output | |
| | H | 4-20mA with HART | | | | | | | | | | | | |
20 | Span[1] | |
| | | Gauge Pressure VRVP1002 | | | | | | | | |
| | | 1B | 0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar) | | | | | | | | |
| | | 1C | 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) | | | | | | | | |
| | | 1D | 0-2.5kPa~250kPa /(0-0.25~25 mH2O)/(0-25~2500mbar) | | | | | | | | |
1F | 0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar) | | |
1G | 0-0.1MPa~10MPa /(0-1~100bar) | | |
1H | 0-0.21MPa~21MPa /(0-2.1~210 bar) | | |
| | | 1I | 0-0.4MPa~40MPa /(0-4~400 bar) | | | | | | | | | |
| | | Absolute Pressure VRVP1003 | | | | | | | | | |
| | | 1L | 0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar) | |
| | | 1M | 0-2.5kPa~250kPa /(0-25~2500mbar) | | | | | | | | | |
| | | 1O | 0-30kPa~3MPa /(0-0.3~30bar) | | | | | | | | | |
30 | Diaphragm fill fluid | |
A | 316L stainless steel Silicone oil | |
C | Hastelloy C Silicone oil | |
40 | Process connector accessory | |
N | 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve | |
B | 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flange | |
U | 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side | |
D | 7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of the flange side | |
50 | Special function | |
| | | | | | N | None | | | | | | | |
0 | Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) | |
60 | Mounting bracket | |
N | None | | |
1 | 304 stainless steel | | |
2 | Carbon steel galvanized | | |
70 | Integral indicator | | | | | | | | | | | | | | | | | | |
| | | | | | | | N | None | | | | | | | | | | | |
| | | | | | | | 1 | LCD display | | | | | | | | | | |
| | | | | | | | 2 | Backlit LCD display | | | | | | | | | | |
80 | Process connector accessory | |
| | | | | | | | | N | None | |
| | | | | | | | | 1 | Stainless steel oval-shaped flange with 1/2 NPT female thread |
| | | | | | | | | 2 | Stainless steel D-shaped connector with M20x1.5 male thread | |
90 | Explosion-proof option | |
| | | | | | | | | | N | None | |
| | | | | | | | | | I | Intrinsic safety Exia | |
| | | | | | | | | | D | Isolated explosion Exd | |
Note 1:VRVP2012 corresponding toselect gauge pressure range code, VRVP2013 corresponding to select absolutepressure range code;
Order example:
For example:VRVP2012-HCANN11NN
[RP2012-]:Gaugepressure transmitter
[H]:4-20mA with HART
[C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)
[A]:316L stainless steel diaphragm, Silicone oil fill fluid
[N]:7/16-20 UNF and 1/4-18 NPT female thread, No relief valve
[N]:None
[1]:With 304 stainless steel mounting bracket
[1]:With LCD display
[N]:None
[N]:None