Coord: > Home > Products- VRVP2000 Smart Pressure Transmitter

VRVP2012- Gauge Pressure Transmitter VRVP2013- Absolute Pressure Transmitter

VRVP2012- Gauge Pressure Transmitter VRVP2013- Absolute Pressure Transmitter

VRVP2012- Gauge Pressure Transmitter

VRVP2013- Absolute Pressure Transmitter

 

 

Thepressure transmitter VRVP2012/3 is suitable to measure liquid, gas, or steamflow as well as liquid level, density and pressure. VRVP2012/3 outputs a 4 to20 mA DC signal corresponding to the measured pressure. The key featuresinclude quick response, remote set-up using communications, self-diagnosticsand optional status output for pressure high/low alarm.

 

STANDARD SPECIFICATIONS

 

1 PERFORMANCE SPECIFICATIONS

Reference Accuracy of Calibrated Span (includesterminal-based linearity, hysteresis, and repeatability)

± 0.075%;

If TD>10 (TD=URL/SPAN):

±(0.0075×TD)%;

 

Ambient Temperature Effects

Span Code

-20℃~65℃

B/L

±(0.30×TD+0.20)%×Span

Others

±(0.20×TD+0.10)%×Span

Span Code

-40℃~-20℃和65℃~85℃

B/L

±(0.30×TD+0.20)%×Span

Others

±(0.20×TD+0.10)%×Span

 

Overpressure Effects

±0.075%×Span

 

Stability

Span Code

Stability

B/L

  ±0.2%×Span/1year

Others

  ±0.1%×Span/1year

 

Power Supply Effects:

±0.001% /10V (12~42V DC)

 

 

 

                   

2 FUNCTIONAL SPECIFICATIONS

Span and Range Limits (VRVP2012)

Span/Range Limits

kPa

bar

1B

Span

0.6~6

6~60mbar

Range Limits

-6~6

-60~60mbar

1C

Span

2~40

0.02~0.4

Range Limits

-40~40

-0.4~0.4

1D

Span

2.5~250

0.025~2.5

Range Limits

-100~250

-1~2.5

1F

Span

30~3000

0.3~30

Range Limits

-100~3000

-1~30

1G

Span

0.1~10MPa

1~100

Range Limits

-0.1~10MPa

-1~100

1H

Span

0.21~21 MPa

2.1~210

Range Limits

-0.1~21 MPa

-1~210

1I

Span

0.4~40 MPa

4~400

Range Limits

-0.1~40 MPa

-1~400

 

Span and Range Limits (VRVP2013)

Span/Range Limits

kPa

bar

1L

Span

2~40

0.02~0.4

Range Limits

0~40

0~0.4

1M

Span

2.5~250

0.025~2.5

Range Limits

0~250

0~2.5

1O

Span

30~3000

0.3~30

Range Limits

0~3000

0~30

External Zero Adjustment

External zero is continuously adjustable with 0.01%incremental resolution of span. Re-range can be done locally using the rangesetting switch.

 

Mounting Position Effects

Rotation in diaphragm plane has no effect. Tilting up to90 degree will cause zero shift up to 0.4 kPa which can be corrected by thezero adjustment.

 

Output

Two wire 4 to 20 mA DC output with digitalcommunications, linear or square root programmable.  HART FSK protocol is option superimposed onthe 4 to 20 mA signal. Output range: 3.9 mA to 20.5 mA

 

Failure Alarm (the mode can be selected)

Low Mode (min): 3.7 mA, High Mode (max): 21 mA

No Mode (hold): Keep the effective value before fault.The standard setting of failure alarm is High Mode.

 

Response Time

Theamplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6sec, it depends on the range and range compression ratio. Amplifier dampingtime constant is adjustable from 0 to 60 sec by software and added to responsetime.

 

Up Time                               < 15s

 

Ambient Temperature Limits: -40 to 85°C

-20 to 65°Cwith LCD display or fluorine rubber sealing

 

Storage and Transportation Temperature Limits

-50 to 85°C, -40 to 85°Cwith LCD display

 

Working PressureLimits (Silicone oil)

From vacuum toupper range limits

 

 

 

 

 

 

Overload Pressure Limits

Span

6kPa

(1B)

40kPa

(1C)

250kPa

(1D/1M)

2(3)MPa

(1E/1O)

OPL

16MPa

16MPa

16MPa

16MPa

Span

10MPa

(1G)

21MPa

(1H)

40MPa

(1I)

OPL

20MPa

50MPa

50MPa

 

Electromagnetic Compatibility (EMC)

Look the EMC Performance Table

 

3 INSTALL

Supply & Load Requirements

24 V DC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximumvoltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(withLCD display)

230Ω to 600Ω for digital communication

 

Electrical Connection

The electrical connection is made via cable entryM20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2.

 

Process Connection

Default Process Connection:Flange withfixing thread 7/16-20 UNF and 1/4-18 NPT female thread on both sides.

 

4 PHYSICAL SPECIFICATIONS

IsolatingDiaphragm:316L stainless steel/Hastelloy C

Process Connector: 316 stainlesssteel

Fill fluid:            Silicone oil

Amplifier Housing:  Aluminum with epoxy resin coat

Housing Gasket:   Perbunan(NBR)

Name plate and tag:304 stainless steel

Weight:           3.3kg

Degrees of Protection: IP67

 

 

 

 

 


 

EMC Performance Table

Items

Test items

Basic standards

Test conditions

Performance Level

1

Radiated interference (Housing)

GB/T 9254-2008

30MHz~1000MHz

OK

2

Conducted interference(DC power port)

GB/T 9254-2008

0.15MHz~30MHz

OK

3

Electrostatic Discharge (ESD) Immunity

GB/T 17626.2-2006

4kV(Line)

8kV(Air)

B

4

RF electromagnetic field immunity

GB/T 17626.3-2006

10V/m (80MHz~1GHz)

A

5

Frequency magnetic field immunity

GB/T 17626.8-2006

30A/m

A

6

Electrical Fast Transient Burst Immunity

GB/T 17626.4-2008

2kV(5/50ns,5kHz)

B

Note:(1)Performancelevel A description: The technical specifications within the limits of normalperformance.

      (2)Performancelevel B description: Temporary reduction or loss of functionality orperformance, it can restore itself. The actual operating conditions, storage,and data will not be changed.

DIMENSIONS                                                                 Unit : mm

HorizontalImpulse Piping Type(side face)     Horizontal Impulse Piping Type(frontside)

 


Horizontal Impulse Wall mounting Type        Vertical ImpulsePiping Type

5 Terminal Configuration

Note:Quick interface functionally equivalentto the signal terminal

 

6 Process connections Description

7 Model and suffix codes

Gauge Pressure Transmitter  VRVP2012- 

 

Absolute Pressure Transmitter  VRVP2013-

 

10

Output

 

 

 

H

4-20mA with HART

 

 

 

 

 

 

 

 

 

 

 

 

20

Span[1]

 

 

 

 

Gauge Pressure VRVP1002

 

 

 

 

 

 

 

 

 

 

 

1B

0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar)

 

 

 

 

 

 

 

 

 

 

 

1C

0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)

 

 

 

 

 

 

 

 

 

 

 

1D

0-2.5kPa~250kPa /(0-0.25~25 mH2O)/(0-25~2500mbar)

 

 

 

 

 

 

 

 

1F

0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar)

 

 

1G

0-0.1MPa~10MPa /(0-1~100bar) 

 

 

1H

0-0.21MPa~21MPa /(0-2.1~210 bar)

 

 

 

 

 

1I

0-0.4MPa~40MPa /(0-4~400 bar)

 

 

 

 

 

 

 

 

 

 

 

 

Absolute Pressure VRVP1003

 

 

 

 

 

 

 

 

 

 

 

 

1L

0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)   

 

 

 

 

1M

0-2.5kPa~250kPa /(0-25~2500mbar)

 

 

 

 

 

 

 

 

 

 

 

 

1O

0-30kPa~3MPa /(0-0.3~30bar)

 

 

 

 

 

 

 

 

 

30

Diaphragm fill fluid 

 

A

316L stainless steel    Silicone oil 

 

C

Hastelloy C          Silicone oil 

 

40

Process connector accessory 

 

N

7/16-20 UNF and 1/4-18 NPT female thread, No relief valve 

 

B

7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flange 

 

U

7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side 

 

D

7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of the flange side

 

50

Special function 

 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

 

0

Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)

 

60

Mounting bracket

 

N

None

 

 

1

304 stainless steel

 

 

2

Carbon steel galvanized

 

 

70

Integral indicator 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

LCD display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Backlit LCD display

 

 

 

 

 

 

 

 

 

 

80

Process connector accessory

 

 

 

 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

 

 

 

 

1

Stainless steel oval-shaped flange with 1/2 NPT female thread

 

 

 

 

 

 

 

 

 

2

Stainless steel D-shaped connector with M20x1.5 male thread 

 

90

Explosion-proof option

 

 

 

 

 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

 

 

 

 

 

I

Intrinsic safety Exia

 

 

 

 

 

 

 

 

 

 

 

D

Isolated explosion Exd

 

Note 1:VRVP2012 corresponding toselect gauge pressure range code, VRVP2013 corresponding to select absolutepressure range code;

 

Order example:

For example:VRVP2012-HCANN11NN

[RP2012-]:Gaugepressure transmitter

[H]:4-20mA with HART

[C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)

[A]:316L stainless steel diaphragm, Silicone oil fill fluid

[N]:7/16-20 UNF and 1/4-18 NPT female thread, No relief valve

[N]:None

[1]:With 304 stainless steel mounting bracket

[1]:With LCD display

[N]:None