Coord: > Home > Products- VRVP2000 Smart Pressure Transmitter

VRVP2002- Gauge Pressure Transmitter VRVP2003- Absolute Pressure Transmitter

VRVP2002- Gauge Pressure Transmitter VRVP2003- Absolute Pressure Transmitter

VRVP2002- Gauge Pressure Transmitter

VRVP2003- Absolute Pressure Transmitter

 

 

Thepressure transmitter VRVP2002/3 is suitable to measureliquid, gas, or steam flow as well as liquid level, density and pressure.VRVP2002/3 outputs a 4 to 20 mA DC signal corresponding to the measuredpressure. The key features include quick response, remote set-up usingcommunications, self-diagnostics and optional status output for pressurehigh/low alarm.

 

STANDARD SPECIFICATIONS

 

1 PERFORMANCE SPECIFICATIONS

Reference Accuracy of Calibrated Span (includesterminal-based linearity, hysteresis, and repeatability)

± 0.075%;

If TD>10 (TD=URL/SPAN):

±(0.0075×TD)%;

 

Ambient Temperature Effects

Span Code

-20℃~65℃

B/L

±(0.30×TD+0.20)%×Span

Others

±(0.20×TD+0.10)%×Span

Span Code

-40℃~-20℃和65℃~85℃

B/L

±(0.30×TD+0.20)%×Span

Others

±(0.20×TD+0.10)%×Span

 

Overpressure Effects

±0.075%×Span

 

Stability

Span Code

Stability

B/L

  ±0.2%×Span/1year

Others

  ±0.1%×Span/1year

 

Power Supply Effects:

±0.001% /10V (12~42V DC)

 

 

                                     

2 FUNCTIONAL SPECIFICATIONS

Span and Range Limits (VRVP2002)

Span/Range Limits

kPa

bar

B

Span

0.6~6

6~60mbar

Range Limits

-6~6

-60~60mbar

C

Span

2~40

0.02~0.4

Range Limits

-40~40

-0.4~0.4

D

Span

2.5~250

0.025~2.5

Range Limits

-100~250

-1~2.5

F

Span

30~3000

0.3~30

Range Limits

-100~3000

-1~30

G

Span

0.1~10MPa

1~100

Range Limits

-0.1~10MPa

-1~100

H

Span

0.21~21 MPa

2.1~210

Range Limits

-0.1~21 MPa

-1~210

I

Span

0.4~40 MPa

4~400

Range Limits

-0.1~40 MPa

-1~400

J

Span

0.6~60 MPa

6~600

Range Limits

-0.1~60 MPa

-1~600

 

Span and Range Limits (VRVP2003)

Span/Range Limits

kPa

bar

L

Span

2~40

0.02~0.4

Range Limits

0~40

0~0.4

M

Span

2.5~250

0.025~2.5

Range Limits

0~250

0~2.5

O

Span

30~3000

0.3~30

Range Limits

0~3000

0~30

External Zero Adjustment

External zero is continuously adjustable with 0.01%incremental resolution of span. Re-range can be done locally using the rangesetting switch.

 

Mounting Position Effects

Rotation in diaphragm plane has no effect. Tilting up to90 degree will cause zero shift up to 0.25 kPa which can be corrected by thezero adjustment.

 

Output

Two wire 4 to 20 mA DC output with digitalcommunications, linear or square root programmable.  HART FSK protocol is option superimposed onthe 4 to 20 mA signal. Output range: 3.9 mA to 20.5 mA

 

Failure Alarm (the mode can be selected)

Low Mode (min): 3.7 mA, High Mode (max): 21 mA

No Mode (hold): Keep the effective value before fault.The standard setting of failure alarm is High Mode.

 

Response Time

Theamplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6sec, it depends on the range and range compression ratio. Amplifier dampingtime constant is adjustable from 0 to 60 sec by software and added to responsetime.

 

Up Time                               < 15s

 

Ambient Temperature Limits: -40 to 85°C

-20 to 65°Cwith LCD display or fluorine rubber sealing

 

Storage and Transportation Temperature Limits

-50 to 85°C, -40 to 85°Cwith LCD display

 

Working PressureLimits (Silicone oil)

From vacuum toupper range limits

 

 

 

 

 

 

Overload Pressure Limits

Span

6kPa

(B)

40kPa

(C)

250kPa

(D/M)

3MPa

(F/O)

OPL

0.2MPa

1MPa

4MPa

16MPa

Span

10MPa

(G)

21MPa(H)

40MPa

(I)

60MPa

(J)

OPL

20MPa

50MPa

50MPa

70MPa

 

Electromagnetic Compatibility (EMC)

Look the EMC Performance Table

 

3 INSTALL

Supply & Load Requirements

24 V DC supply, R≤(Us-12V)/Imax kΩ, Imax=23 mA. Maximumvoltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDC(withLCD display)

230Ω to 600Ω for digital communication

 

Electrical Connection

The electrical connection is made via cable entryM20x1.5.The screw terminals are suitable for wire cross-sections up to 2.5mm2.

 

Process Connection

Default Process Connection:1/2-NPT femalethread, it can be changed to 1/2-NPT,G1/2,M20x1.5male thread and KF16 vacuumConnection.

 

4 PHYSICAL SPECIFICATIONS

IsolatingDiaphragm:316L stainless steel/Hastelloy C

Process Connector: 316 stainlesssteel

Fill fluid:            Silicone oil

Amplifier Housing:  Aluminum with epoxy resin coat

Housing Gasket:   Perbunan(NBR)

Name plate and tag:304 stainless steel

Weight:           1.6kg

Degrees of Protection: IP67

 

 

 

 

 


 

EMC Performance Table

Items

Test items

Basic standards

Test conditions

Performance Level

1

Radiated interference (Housing)

GB/T 9254-2008

30MHz~1000MHz

OK

2

Conducted interference(DC power port)

GB/T 9254-2008

0.15MHz~30MHz

OK

3

Electrostatic Discharge (ESD) Immunity

GB/T 17626.2-2006

4kV(Line)

8kV(Air)

B

4

RF electromagnetic field immunity

GB/T 17626.3-2006

10V/m (80MHz~1GHz)

A

5

Frequency magnetic field immunity

GB/T 17626.8-2006

30A/m

A

6

Electrical Fast Transient Burst Immunity

GB/T 17626.4-2008

2kV(5/50ns,5kHz)

B

Note:(1)Performancelevel A description: The technical specifications within the limits of normalperformance.

      (2)Performancelevel B description: Temporary reduction or loss of functionality orperformance, it can restore itself. The actual operating conditions, storage,and data will not be changed.

DIMENSIONS                                                                 Unit : mm

HorizontalImpulse Piping Type(side face)     Horizontal Impulse Piping Type(frontside)

 


Horizontal Impulse Wall mounting Type        Vertical ImpulsePiping Type

5 Terminal Configuration

Note:Quick interface functionally equivalentto the signal terminal

 

6 Process connections Description

6.1 Default Process Connection(Code 1)

M/D/F/G/H/I/J/O Span             B/C/L Span

6.2 Other forms of Process connector

1/2-NPT male thread(Code 2)                     M20x1.5 male thread(Code3) 

 

G 1/2 male thread(Code 4)     Vacuum Connection DIN 28403 KF16 / ISO 2861(Code 5)

                         

 

1/4-NPT male thread(Code 6)

7 Model and suffix codes

Gauge Pressure Transmitter  VRVP2002- 

Absolute Pressure Transmitter  VRVP2003-

10

Output

 

 

H

4-20mA with HART

 

 

 

 

 

 

 

 

 

 

 

20

Span[1]

 

 

 

Gauge Pressure VRVP1002

 

 

 

 

 

 

 

 

 

 

B

0-0.6kPa~6kPa /(0-60~600 mmH2O)/(0-6~60mbar)

 

 

 

 

 

 

 

 

 

 

C

0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)

 

 

 

 

 

 

 

 

 

 

D

0-2.5kPa~250kPa /(0-0.25~25 mH2O)/(0-25~2500mbar)

 

 

 

 

 

 

 

F

0-30kPa~3MPa /(0-3~300 mH2O)/(0-0.3~30bar)

 

G

0-0.1MPa~10MPa /(0-1~100bar) 

 

H

0-0.21MPa~21MPa /(0-2.1~210 bar)

 

 

 

 

I

0-0.4MPa~40MPa /(0-4~400 bar)

 

 

 

 

 

 

 

 

 

 

 

J

0-0.6MPa~60MPa /(0-6~600 bar)

 

 

 

Absolute Pressure VRVP1003

 

 

 

 

 

 

 

 

 

 

 

L

0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)   

 

 

 

M

0-2.5kPa~250kPa /(0-25~2500mbar)

 

 

 

 

 

 

 

 

 

 

 

O

0-30kPa~3MPa /(0-0.3~30bar)

 

 

 

 

 

 

 

 

30

Diaphragm fill fluid 

A

316L stainless steel    Silicone oil 

C

Hastelloy C          Silicone oil 

40

Process connector accessory 

1

1/2-NPT female thread

2

1/2-NPT male thread (Containing 1/4-NPT female thread) 

3

M20x1.5 female thread

 

4

G 1/2 female thread

 

 

 

 

 

 

5

Vacuum Connection DIN 28403 KF16 / ISO 2861[2]

 

 

 

 

 

 

 

 

 

 

 

6

1/4-NPT male thread 

 

 

 

 

 

 

50

Special function 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

0

Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃)

60

Mounting bracket

N

None

 

1

304 stainless steel

 

2

Carbon steel galvanized

 

70

Integral indicator 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

LCD display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Backlit LCD display

 

 

 

 

 

 

 

 

 

80

Explosion-proof option

 

 

 

 

 

 

 

 

 

N

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Intrinsic safety Exia

 

 

 

 

 

 

 

 

 

D

Isolated explosion Exd

Note 1:VRVP1002 corresponding toselect gauge pressure range code, VRVP1003 corresponding to select absolutepressure range code;

Note 2:Vacuum Connection DIN 28403 KF16 / ISO 2861, applies onlyto the range of less than 2,5 bar;

 

Order example:

For example:VRVP2002-HCA1N11N

[VRVP2002-]:Gaugepressure transmitter

[H]:4-20mA with HART

[C]:Span:0-2kPa~40kPa /(0-200~4000 mmH2O)/(0-20~400mbar)

[A]:316L stainless steel diaphragm, Silicone oil fill fluid

[1]:1/2-NPT female thread process connector

[N]:None

[1]:With 304 stainless steel mounting bracket

[1]:With LCD display

[N]:None